Analysis Careers Contact
About Us Services Information
 

PRESERVATION AND HOLDING TIMES

METALS

(Click here to view or download this information in PDF format.)



Parameter

Matrix

Prep Method

Analytical Method

Holding
Time5

Minimum Volume

Sampling

 

 

 

 

 

 

Container

Preservative7

Cations

Water

EPA 3010A

EPA 6010B

6 mo

100 mL

250mL P

HNO3

EPA 200.7

EPA 200.7

6 mo

100 mL

250mL P

HNO3

EPA 200.8

EPA 6020

6 mo

100 mL

250mL P

HNO3

EPA 200.8

EPA 200.8

6 mo

100 mL

250mL P

HNO3

Soil

EPA 3050B

EPA 6010B

6 mo

2 g

 

 

EPA 3050B

EPA 6020

6 mo

2 g

 

 

ICP Metals

Water

EPA 3010A

EPA 6010B

6 mo

100 mL

250mL P

HNO3

EPA 200.7

EPA 200.7

6 mo

100 mL

250mL P

HNO3

Soil

EPA 3050B

EPA 6010B

6 mo

2 g

 

ICP-MS Metals

Water

EPA 200.8

EPA 6020

6 mo

100 mL

250mL P

HNO3

EPA 200.8

EPA 200.8

6 mo

100 mL

250mL P

HNO3

Soil

EPA 3050B

EPA 6020

6 mo

2 g

 

 

Hexavalent Chromium

Water

METHOD1

EPA 7196A

24 hr

100 mL

500 mL P

None

METHOD1

EPA 7199

24 hr

50 mL

250 mL P

None

Soil

METHOD1

EPA 7196A

30 days

40 g

 

Lead

Water

EPA 3010A

EPA 6010B

6 mo

100 mL

250mL P

HNO3

EPA 200.7

EPA 200.7

6 mo

100 mL

250mL P

HNO3

EPA 200.8

EPA 6020

6 mo

100 mL

250mL P

HNO3

EPA 200.8

EPA 200.8

6 mo

100 mL

250mL P

HNO3

Soil

EPA 3050B

EPA 6010B

6 mo

2 g

 

 

EPA 3050B

EPA 6020

6 mo

2 g

Mercury

Water

METHOD1

EPA 7470A

28 days

100 mL

250mL P

HNO3

METHOD1

EPA 245.1

28 days

100 mL

250mL P

HNO3

Soil

METHOD1

EPA 7471A

28 days

0.5 g

 

 

Organic Lead

Water

CA LUFT1

CA LUFT1

14 days

100 mL

500mL P

None

Soil

CA LUFT1

CA LUFT1

14 days

50 g

 

 

Priority Pollutant Metals

Water

EPA 3010A/ Method1

EPA 6010B/7470A

6 mo/28d4

100 mL

500mL P

HNO3

EPA 200.8/ Method1

EPA 6020/7470A

6 mo/28d4

100 mL

500mL P

HNO3

Soil

EPA 3050B/ Method1

EPA 6010B/7471A

6 mo/28d4

  5 g

 

 

EPA 3050B/ Method1

EPA 6020/7471A

6 mo/28d4

  5 g

RCRA (8) Metals

Water

EPA 3010A/ Method1

EPA 6010B/7470A

6 mo/28d4

100 mL

500mL P

HNO3

EPA 200.8/ Method1

EPA 6020/7470A

6 mo/28d4

100 mL

500mL P

HNO3

Soil

EPA 3050B/ Method1

EPA 6010/7400

6 mo/28d4

  5 g

 

 

EPA 3050B/ Method1

EPA 6020/7400

6 mo/28d4

  5 g

STLC Extraction for CA-W.E.T. Metals

Soil

CA T22:22-66261

various

6 mo/28d4

50 g

 

SPLP Extraction for Metals

Soil

EPA 1312

various

6 mo/28d4

100 g5

 

TCLP Extraction for Metals

Soil

EPA 1311

various

6 mo/28d4

100 g5

 

TCLP Extraction for Semivolatiles

Soil

EPA 1311

various

14 days

100 g5

 

CA Title 26 Metals (CAM 17)

Water

EPA 3010A/Method1

EPA 6010B/7470A

6 mo/28d4

100 mL

500mL P

HNO3

EPA 200.8/ Method1

EPA 6020/7470A

6 mo/28d4

100 mL

500mL P

HNO3

Soil

EPA 3050B/ Method1

EPA 6010B/ 7471A

6 mo/28d4

  5 g

 

 

EPA 3050B/ Method1

EPA 6020/7471A

6 mo/28d4

  5 g

Tributyl Tin ("Organo-tin")

Water

EPA 3520C

GC/FPD

NS

1 L

 

 

Soil

EPA 3550B

GC/FPD

NS

10 g

1L P or G

None



Notes

1.

"Method" indicates that the prep method is an integral part of the analytical method.

California Department of Health Services Leaking Underground Fuel Tank Manual, October 1989

2.

Holding times specified in 40CFR 136.3 Table 2 (Clean Water Act/ NPDES) and SW-846 Table 2-36 Revision 3, December 1996.

3.

Samples should be preserved within 15 minutes of collection and kept at 4°C from time of collection until analysis.

Preserved containers can be supplied by C&T.

HCL: hydrochloric acid to pH < 2, H2SO4: sulfuric acid to pH < 2, NaOH: sodium hydroxide to pH > 12, HNO3: nitric acid to pH < 2

4.

28 day holding time for mercury; 6 month holding time for all other elements.

5.

100g minimum for TCLP extraction. 50g required for each analysis.



Legend

G:

Amber Glass

P:

Polyethylene